Generac Guardian 20kW Standby Generator
Pre Packaged with 200 Amp Service Rated ATS
Model: 6244
FEATURES
-
INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it
doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance.
-
TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems.
PROTOTYPE TESTED NEMA MG1-22 EVALUATION
SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY
-
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%.
-
SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component.
-
GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.
14/17/20 kW
features and benefits
Engine | |
•Generac (OHVI) design | Maximizes engine “breathing” for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. |
• Quiet-Test™ (17 & 20 kW units only) | Greatly reduces sound output and fuel consumption during weekly exercise, compared to other brands. |
•“Spiny-lok” cast iron cylinder walls | Rigid construction and added durability provide long engine life. |
•Electronic ignition/spark advance | These features combine to assure smooth, quick starting every time. |
•Full pressure lubrication system |
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. |
•Low oil pressure shutdown system | Shutdown protection prevents catastrophic engine damage due to low oil. |
•High temperature shutdown | Prevents damage due to overheating. |
Generator | |
•Revolving field | Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. |
• Skewed stator | Produces a smooth output waveform for compatibility with electronic equipment. |
•Displaced phase excitation | Maximizes motor starting capability. |
•Automatic voltage regulation | Regulates the output voltage to ±1% prevents damaging voltage spikes. |
•UL 2200 listed | For your safety. |
Transfer Switch | |
•Fully automatic | Transfers your vital electrical loads to the energized source of power. |
•Pre-wired, color-coded conduits (Pre-wired switches only) | Ensures the easiest, trouble-free installation. |
• DPM Technology (Smart Switch only) | Digital Power Management Technology allows for the smart control of two air conditioners without any additional items. |
•Remote mounting | Mounts near your existing distribution panel for simple, low-cost installation. |
Evolution™ Controls | |
•Auto/Manual/Off illuminated buttons | Selects the operating mode and provides easy, at-a-glance status indication in any condition. |
• Sealed, raised buttons | Smooth, weather-resistant user interface for programming and operations. |
•Utility voltage sensing | Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage. |
•Generator voltage sensing | Constantly monitors generator voltage to ensure the cleanest power delivered to the home. |
•Utility interrupt delay | Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. |
•Engine warm-up | Ensures engine is ready to assume the load, setpoint approximately 5 seconds. |
•Engine cool-down | Allows engine to cool prior to shutdown, setpoint approximately 1 minute. |
•Programmable seven day exerciser | Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12 minutes every week. |
•Smart battery charger | Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. |
•Main line circuit breaker | Protects generator from overload. |
•Electronic governor | Maintains constant 60 Hz frequency. |
Unit | |
•SAE weather protective enclosure | Sound attenuated enclosure ensures quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. |
•Enclosed critical grade muffler | Quiet, critical grade muffler is mounted inside the unit to prevent injuries. |
•Small, compact, attractive | Makes for an easy, eye appealing installation. |
Installation System | |
•1 ft (305 mm) flexible fuel line connector | Easy installation. |
•Composite mounting pad |
14/17/20 kW
specifications
Generator |
006240-0, 006241-0, |
006242-0, 006243-0, 006248-0, 006249-0 |
006244-0, 006250-0 |
|
Model | ||||
006247-0, (14 kW) | (17 kW) | (20 kW) | ||
Rated Maximum Continuous Power Capacity (LP) | 14,000 Watts* | 17,000 Watts* | 20,000 Watts* | |
Rated Maximum Continuous Power Capacity (NG) | 14,000 Watts* | 16,000 Watts* | 18,000 Watts* | |
Rated Voltage | 240 | 240 | 240 | |
Rated Maximum Continuous Load Current – 240 Volts (LP/NG) | 58.3/58.3 | 70.8/66.6 | 83.3/75 | |
Total Harmonic Distortion | Less than 5% | Less than 5% | Less than 5% | |
Main Line Circuit Breaker | 60 Amp | 65 Amp | 90 Amp | |
Phase | 1 | 1 | 1 | |
Number of Rotor Poles | 2 | 2 | 2 | |
Rated AC Frequency | 60 Hz | 60 Hz | 60 Hz | |
Power Factor | 1.0 | 1.0 | 1.0 | |
Battery Requirement (not included) | Group 26R, 12 Volts and 525 CCA Minimum | |||
Unit Weight (lb/kg) | 435/197.3 | 471/213.6 (Steel); 437/198.2 (Aluminum) | 451/204.6 | |
Dimensions (L x W x H) in/mm | 48 x 25 x 29/1218 x 638 x 732 | |||
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load** | 66 | 66 | 66 | |
Sound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test™ low-speed exercise mode** |
N/A |
60 |
60 |
|
Engine | ||||
Type of Engine | GENERAC OHVI V-TWIN | GENERAC OHVI V-TWIN | GENERAC OHVI V-TWIN | |
Number of Cylinders | 2 | 2 | 2 | |
Displacement | 992 cc | 992 cc | 999 cc | |
Cylinder Block | Aluminum w/ Cast Iron Sleeve | |||
Valve Arrangement | Overhead Valve | Overhead Valve | Overhead Valve | |
Ignition System | Solid-state w/ Magneto | Solid-state w/ Magneto | Solid-state w/ Magneto | |
Governor System | Electronic | Electronic | Electronic | |
Compression Ratio | 9.5:1 | 9.5:1 | 9.5:1 | |
Starter | 12 Vdc | 12 Vdc | 12 Vdc | |
Oil Capacity Including Filter | Approx. 1.9 qt/1.8 L | Approx. 1.9 qt/1.8 L | Approx. 1.9 qt/1.8 L | |
Operating rpm | 3,600 | 3,600 | 3,600 | |
Fuel Consumption | ||||
Natural Gas ft³/hr (m³/hr) | ||||
1/2 Load | 177 (5.01) | 193 (5.47) | 205 (5.8) | |
Full Load | 279 (7.9) | 312 (8.83) | 308 (8.72) | |
1/2 Load | 67.2 (1.85) [6.99] | 72.4 (1.99) [7.53] | 75.6 (2.08) [7.87] | |
Full Load | 111.6 (3.07) [11.61] | 130 (3.57) [13.53] | 140 (3.85) [14.57] | |
Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges – 3.5-7″ water column (7-13 mm mercury) for natural gas, 10-12″ water column (19-22 mm mercury) for LP gas. For Btu content, multiply ft3/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply m³/hr x 93.15 (LP) or m³/hr x 37.26 (NG) |
||||
Controls | ||||
2-Line Plain Text Multilingual LCD Display | Simple user interface for ease of operation. | |||
Mode Buttons: Auto | Automatic Start on Utility failure. 7 day exerciser. | |||
Manual | Start with starter control, unit stays on. If utility fails, transfer to load takes place. | |||
Off | Stops unit. Power is removed. Control and charger still operate. | |||
Ready to Run/Maintenance Messages | Standard | |||
Engine Run Hours Indication | Standard | |||
Programmable start delay between 2-1500 seconds | Standard (programmable by dealer only) | |||
Utility Voltage Loss/Return to Utility Adjustable | From 140-171 V/190-216 V | |||
Future Set Capable Exerciser/Exercise Set Error Warning | Standard | |||
Run/Alarm/Maintenance Logs | 50 Events Each | |||
Engine Start Sequence | Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). | |||
Starter Lock-out | Starter cannot re-engage until 5 sec after engine has stopped. | |||
Smart Battery Charger | Standard | |||
Charger Fault/Missing AC Warning | Standard | |||
Low Battery/Battery Problem Protection and Battery Condition Indication | Standard | |||
Automatic Voltage Regulation with Over and Under Voltage Protection | Standard | |||
Under-Frequency/Overload/Stepper Overcurrent Protection | Standard | |||
Safety Fused/Fuse Problem Protection | Standard | |||
Automatic Low Oil Pressure/High Oil Temperature Shutdown | Standard | |||
Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown | Standard | |||
High Engine Temperature Shutdown | Standard | |||
Internal Fault/Incorrect Wiring Protection | Standard | |||
Common External Fault Capability | Standard | |||
Field Upgradable Firmware | Standard |
**Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions – Standby: Applicable
for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 °C (60 °F).
14/17/20 kW
available accessories
|
* Note: Bisque kits are used in conjunction with steel enclosures. Gray kits are used in conjunction with aluminum enclosures.
Smart Switch Features
- Includes Digital Power Management Technology standard (DPM).
- Intelligently manages two air conditioner loads with no additional
hardware.
- Up to four more large (120/240 VAC) loads can be managed when used in conjunction with Power Management Modules (PMM**).
- Electrically operated, mechanically-held contacts for fast, clean
connections.
- Rated for all classes of load, 100% equipment rated, both inductive
and resistive.
- 2 pole, 250 VAC
- Service equipment rated, dual coil
- Rated for both aluminum and copper
- NEMA/UL 3R aluminum outdoor
- Main contacts are silver plated or silver alloy to resist welding and
sticking.
**Note: PMM starter kit is required prior to using the modules.
|
Dimensions
|
200 Amps 120/240, 1ø Open Transition Service Rated |
||||
Height |
Width |
Depth |
|||
|
H1 |
H2 |
W1 |
W2 |
|
in |
27.24 |
30.0 |
11.4 |
13.5 |
7.09 |
mm |
692.0 |
762.4 |
289.0 |
343.0 |
180.0 |
|
*Function of Evolution Controller